Room Temperature Sensor
RTS:

Dimensions:
RTS-Raw
RTS-Bead

$1.00 - $3.50
The room sensors are used to provide reliable, accurate temperature readings in surface-mount room environments, Energy Management Control Systems, compatible with all the leading control systems.They feature a standard plastic ventilated enclosure.
| Weight | 0.01 kg |
|---|---|
| RTS type | RTS, RTS-Bead-120, RTS-Bead-4, RTS-RAW |
| Temperature Curve |
Availability: In stockOut of stock
The temperature sensor is designed to measure outdoor air temperature in typical HVAC applications. Mounting is quick and easy using two screws and no electrical box. The thermistor is a well sealed stainless steel probe which is then inserted into a hard rubber PVC radiation shield. The cable is two meters long which allows terminating inside the building in an electrical enclosure or with flying leads. The cable can exit directly behind the probe and into the building through a hole, or it can exit vertically and run down the wall. A foam backing seals the hole in the wall if there is one and also serves to thermally insulate the probe from the wall. The probe is filled with thermal grease for quick response.
Availability: In stockOut of stock
Duct mount temperature only transducer, Bacnet/Modbus over RS485, 0-10v 4-20ma output signal
Availability: In stockOut of stock
This Probe Temperature Sensor is a 1K Platinum coming standard with an 8″ length Stainless Steel Temperature Sensor.
Availability: In stockOut of stock
This sensor is used to measure the supply and return temperature in HVAC system. The flange mount design makes it easy to install the sensor in tight quarters. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. The probe in the photo is our standard model which is always in stock, it has a 8″ probe and a 120″ cable, and employs either a precision thermistor or platinum film sensor, so field calibration is not required. The 10ft(3m) cable is “Plenum Rated”.
Availability: In stockOut of stock
Notice: Temporary price increase of ~$8USD due to the global CPU shortage Accept our apologies, we’re not sure how long this will last but it could be a couple months
Bacnet Room Setpoint & Temp Display can be used in environment monitoring and controlling in industrial,commercial and other buildings,Modbus RS485/Bacnet MS/TP for direct digital reading on all models.
Availability: In stockOut of stock
This temperature probe is suitable for a variety or high temperature applications such as floor heating, solar heating systems and domestic hot water heaters to name a few. The sensor element is housed in a stainless steel probe which is 6mm diameter x 50mm [2in] long. The cable is 4.5 meter long and is a high temperature material that is tough and highly durable.The probe is available with custom thermistors and Pt elements, nearly all the popular ranges are available with very small minimum order quantity.
Availability: In stockOut of stock
This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start/stop, and supply temperature reset. The housing is made from PVC and stainless steel fittings which shield the probe from direct sunlight. There are three thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems.
Availability: In stockOut of stock
The room temperature sensor provide precision room temperature sensing in a discreet button form factor for all popular DDC systems.
Availability: In stockOut of stock
This sensor is used to measure water temperature of heated or chilled water and other liquids in mechanical systems. The sensor is called an immersion type where the sensor is mounted in a brass or stainless steel thermowell which allows the probe to be removed from the pipe without draining the system and protects the probe.There are four thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems.